YBF-12 photovoltaic in-situ booster substation
Product Introduction:
Tel:400-000-6707
Add:No. 258, Weiqi Road, Economic Development Zone, Yueqing City, Zhejiang Province
IntroductionPhotovoltaic power generation as a clean method of energy production, has seen rapid development both at home and abroad. The YBF-12 photovoltaic in-situ booster substation is specifically designed to meet the growing power supply requirements of photovoltaic power generation. The 10kV and 35kV combined transformers produced by our company are designed with the transformer, load switch, and high-voltage fuse installed within the transformer case. The insulation liquid of the transformer serves as the insulating and cooling medium for the entire product. It has a fully sealed structure. The outer case is divided. It is shot-blasted, acid pickled, phosphorized, and then coated with primer, intermediate paint, and topcoat to realize superior corrosion resistance, durability, and UV protection over conventional spraying methods. The product is characterized by their small size, light weight, and ease of installation.
Model meaning
Use conditions >Altitude not above 3000m;
>Ambient temperature scope: -40℃~+45℃;
>Outdoor wind speed not above 30m/s
>Relative temperature: daily average not above 95%; monthly average not above 90%;
>The waveform of the power supply voltage is approximately sinusoidal, and the three-phase power supply voltage is approximately symmetrical;
>Installation place: installed at places without fire, explosion hazard, serious pollution, chemical corrosion and violent vibration.
Note: the user may negotiate with the manufacturer in case the use conditions exceed the above regular use environmental conditions.
Technical parameters
Outline dimension drawing
Order informationThe user needs to provide the following information for ordering:
>Model, capacity, quantity, color and outline dimension requirements, case material;
>Model, performance, binding group, branching scope and impedance requirements of the transformer;
>First wiring schemes of high voltage and low voltage sides, models, specifications and requirements of components and parts;
>Transformer oil (25#, 45#, high ignition point oil);
>Requirements for net-in configuration of box-type substations by intelligent power management network or property management;
> Use environment requirements.